Turnigy 2810 EDF Outrunner 3500KV voor 55 / 64mm

Turnigy 2810 EDF Outrunner 3500KV voor 55 / 64mm

Shipped From:
  • Global
Discontinued Product

Please continue searching for a similar product.
SKU:
T28101C3500
WANT FREE SHIPPING? Click here to find out more!
Turnigy 2810 EDF Outrunner 3500KV voor 55 / 64mm
specs:
kV 3500
Afmetingen: 46 x 28mm
Shaft: 2.3 / 3.0mm
Voltage: 11.1V
Gewicht: 59g
No-load stroom: 1.5A
No-load RPM: 39.220
Laad stroom: 16.4A
Load RPM: 32.660
Thrust: 444G
Montagegaten Bolt Circle: 18mm
Mtg. Hole Number & Grootte: 4 x M2.5
 
Inclusief 2 assen, 2.3 & 3.0mm
  • Sku T28101C3500
  • Brand Turnigy
  • Gewicht 95.0000
  • Lengte 0.00
  • Packaging Width 0.00
  • Hoogte 0.00
  • Kv ( tpm / v ) 3500.00
  • Max Currents (A ) 16.40
  • Resistance ( mh ) 0.00
  • Max Voltage ( V ) 11.00
  • Vermogen ( W) 0.00
  • Shaft A ( mm ) 3.00
  • Lengte B ( mm ) 46.00
  • C Diameter ( mm ) 28.00
  • Kan Lengte D ( mm ) 12.00
  • Totale lengte E ( mm ) 60.00
Upload video

Only registered users can upload video. Please, log in or register

Only registered users can write reviews. Please, sign in or sign up

I have purchased 6 of this type of motor

Two have given problems, the same problem

The lead insulation on some motors is not long enough

It does not insert into the motor housing far enough

Bench testing never fails

When the motor is inserted into the fan unit, the leads are bent to fit

This causes the insulation to exit the motor housing and a short cct happens as the bare copper touches the motor housing. Sometimes an immediate problem, or after a few test runs

Solution - ensure that the outer insulation iof the lead is well within the motor casing

BE BRUTAL

verified_user Quality:
trending_up Value:
playlist_add_check Overall:

I have purchased 6 of this type of motor

Two have given problems, the same problem

The lead insulation on some motors is not long enough

It does not insert into the motor housing far enough

Bench testing never fails

When the motor is inserted into the fan unit, the leads are bent to fit

This causes the insulation to exit the motor housing and a short cct happens as the bare copper touches the motor housing. Sometimes an immediate problem, or after a few test runs

Solution - ensure that the outer insulation iof the lead is well within the motor casing

BE BRUTAL

Just been playing with mine.. this a Very Well made unit .. bargain priced.

Bearings are smooth, Windings are neat and well done. 36,000 rpms so far :-) quietly and smoothly.

MUCH better quality than the Turnigy motors Recommended

verified_user Quality:
trending_up Value:
playlist_add_check Overall:

Just been playing with mine.. this a Very Well made unit .. bargain priced.

Bearings are smooth, Windings are neat and well done. 36,000 rpms so far :-) quietly and smoothly.

MUCH better quality than the Turnigy motors Recommended

Boa opcao, mas nao a melhor opcao.. da para se ter melhor desempenho com mais KV

verified_user Quality:
trending_up Value:
playlist_add_check Overall:

Boa opcao, mas nao a melhor opcao.. da para se ter melhor desempenho com mais KV

Upload your file

Only registered users can upload files.
Please log in or register to start helping your fellow hobbyists today!

Radio Control Planes, Drones, Cars, FPV, Quadcopters and more - Hobbyking